RECORA
Safety Controllers and Safety Relays (FSC-6):


Design Principles:

The Recora FSC-6 Failsafe Safety Mat Controller is designed as a complete, self-contained, mat controller suitable to use at all levels of risk mitigation requirements in industrial applications. The FSC-6 integrates a number of sophisticated safety design concepts to ensure the highest degree of safe operation along with the best possible protection for equipment and personnel. The FSC-6 is available in various configurations to match the appropriate level of protection to the potential risk without sacrificing productivity.











FSC-6 Specifications and Features

Safety Features

  • Full dual channel operation
  • Positive operation state indicators
  • Force guided relay
  • Redundant critical control components
  • Configuration for ANSI B11.19 guidelines
  • Controlled access for installation, operation
  • NEMA 12 and 13 enclosure
  • Factory configured and inspected

Additional Protection Features (Optional)

  • Illuminated reset button
  • Additional light tower indicators
  • Key operated mandatory reset
  • Padlock kit for lock-out

Enclosure
Standard - NEMA-12 -
8" x 8" x 6"
Optional - 4X

Enclosure Fastening Technique
Standard - Front panel screw - tamper resistant
Optional - Key-lock, mechanical lockout

FSC Series - Safety Control

Model Sizes Description
FSC-6-R 1.75" x 3" x 4.75" Din Rail Relay
FSC-6-1Z 8" x 8" x 4" 1 Zone
FSC-6-2Z 10" x 8" x 6" 2 Zone
FSC-6-3Z 14" x 8" x 6" 3 Zone
FSC-6-4Z 14" x 8" x 6" 4 Zone
Special control configurations available.


Machine Controls Outputs
Standard - 2 channel safe circuit
Contacts - 2 N.O. safety contacts
Contact type - Forced contact
Contact material - Ag-Alloy; Gold-plated
Switching voltage - 230/230 V AC/DC
Maximum continuous current per contact - 6 amps
Mechanical lifetime - 10 x 106 switching cycles
Recovery time (without RESET monitoring) - 8000 mSec
Working range ambient temperature:   -25 to +55 °C


Internal Configuration
DIN 35mm rail design
Cage-Clamp wire design, touch safe
Isolated power, Switchmat, and machine control inputs
Power
Standard - 120 VAC 60 HZ
Optional - 24 VDC
Rated voltage - 120 VAC
Rated consumption at 50 Hz - 2.5 watts
Rated  frequency - 50 to 60 Hz
AC:  Short-circuit proof transformer
Presence Sensor Inputs
Standard - Single safety mat
Optional - Multiple zone inputs
Light screen
Gate switch
Limit switch
Positive sensor identification
Front Panel Indicators
Standard -
Normal: GREEN
Halt: RED
Front Panel Controls
Optional -
Manual RESET
Key operated RESET

Risk Assessment
The level of safety protection required for a given application is based on the risk associated with that application. The risk associated with an operation is based on a number of factors that must be taken together and evaluated in total to establish the risk level for any equipment or operation.

Partial Listing of Applicable Safety Standards

ANSI B11.19-1990 Machine Tools - Safeguarding when referenced by other B11 machine tool safety standards - performance criteria for the design, construction, care, and operation

ANSI/RIA R15.06-1992 - for Industrial Robots and Robot Systems - Safety Requirements
ANSI Z244.1-1982 Personnel protection - Lockout/tagout of energy sources - Minimum safety requirements

ANSI/ASME B15.1 - 1984 Safety standard for mechanical power transmission apparatus

ANSI/NFPA 79-1991 Electrical standard for industrial machinery


-- Home -- Machine Safeguarding -- Technical Directories --
-- Products -- Contact -- Ordering -- Quote Request --

Industrial Safety Controls, Inc.
P.O. Box 126 -- 4112 Sheridan Road
Kenosha, WI 53141
(262) 652-8660 -- Fax: (262) 652-1388
E-mail: safetysensing@earthlink.net